Service manual

Contents
Purpose/kind Section Main
code
Sub
code
Description
Ref. page
Setting Specifications 26 6 Used to set the destination.
(Operation/procedure)
When the simulation key operation is performed, the code number of the
currently set destination is displayed.
Enter the code number corresponding to the desired destination and press the
print button, and the specifications for the destination will be set.
Code number
Destination
Normal machine Zoom machine
4 14 Japan
1 11 U.K.
5 15 AB series other than U.K.
6 16 USA
7 17 Inch series other than USA
25 35 Indonesia
Paper feed unit 26 12 Used to set the manual paper feed mode. (SF-2014 only)
There are two operation modes: auto and manual. Either of the two can be
set.
(Operation/procedure)
When the simulation key operation is performed, the code number of the
currently set operation mode is displayed.
Enter the code number corresponding to the desired operation mode and
press the print button, and the operation mode will be set.
Code number Operation mode Operation
1 Manual
When the print button is pressed,
copying is started.
0 Auto
When copy paper is set, coping is
automatically started.
Fuser unit 26 13 Used to set the operation mode of the main motor in warming up.
There are two operation modes: auto and manual. Either of the two can be
set.
(Operation/procedure)
When the simulation key operation is performed, the code number of the
currently set operation mode is displayed.
Enter the code number corresponding to the desired operation mode and
press the print button, and the operation mode will be set.
Code number Operation mode Operation
0 Normal mode
The main motor rotates until the
process cleaning is completed.
1 Long mode
The main motor keeps rotating
until completion of warming up.
43 1 Used to set the fusing temperature.
(Operation/procedure)
When the simulation key operation is performed, the lower two digits of the
currently set temperature is displayed on the COPIES SELECTED display.
(Example: 75 ——— 175 ˚C)
Pressing the paper select key under that state allows selection of fusing
temperature by the increment of 5 ˚C. To set the temperature, press the print
button. (Standard set value: 85 ——— 185˚C)
2 Used to set the fusing temperature in the power save mode.
(Operation/procedure)
When the simulation key operation is performed, the lower two digits of the
currently set temperature is displayed on the COPIES SELECTED display.
Pressing the paper select key under that state allows selection of fusing
temperature by the increment of 5 ˚C. To set the temperature, press the print
button.
*00 05 10 85 90 95 *: Standard set value
8 – 8