Service manual

5. Memory simulation list
Purpose/kind Section
Contents
Ref. page
Main
code
Sub
code
Default
value
Description
Adjustment Paper feed
section
51 2 50 Adjustment value of contact pressure of the paper on the main
body resist roller
8-3
Optical unit 26 8 11 Adjustment value (lens shift amount adjustment value) of copy
magnification ratio in zoom copying
7-16
45 1 50 Adjustment value of copy paper lead edge void amount 7-20
46 1 Adjustment value of copy density (exposure level) in each copy
mode and of copy density gradient (exposure gradient)
7-26
Manual copy mode density level 1 (Not toner save mode)
Manual copy mode density level 5 (Not toner save mode)
Manual copy mode density level 1 (Toner save mode)
Manual copy mode density level 5 (Toner save mode)
Auto copy mode density level 1 (Not toner save mode)
Auto copy mode density level 5 (Not toner save mode)
Auto copy mode density level 1 (Toner save mode)
Auto copy mode density level 5 (Toner save mode)
Photo copy mode density level 1 (Not toner save mode)
Photo copy mode density level 5 (Not toner save mode)
47 The AE sensor and the optical section characteristics memory data
for the change in the copy lamp application voltage
7-26
48 1 50 The vertical copy magnification ratio adjustment value 7-15
2 50 The horizontal copy magnification ratio adjustment value (when the
document table is used)
7-16
50 1 The adjustment value of copy image position on the copy paper 7-19
50 Set value A
50 Set value B
50 Set value C
Process 44 1 Process correction mode setting
Developer unit 25 2 Toner density initial set value 4-5
SPF unit 48 3 50 The horizontal copy magnification ratio adjustment value (when the
document table is used)
7-18
51 2 50 The adjustment value of contact pressure between the SPF resist
roller and the document
8-3
6 Adjusting value of copy density in the SPF mode 7-28
Setting Specifications 26 1 Setting the option 8-7
6 Specifications setting by destination 8-8
Fuser unit 26 13 0 Setting of the main motor operation mode in warming up. 8-8
43 1 185˚C Fusing temperature set value 8-8
2 Fusing temperature setting value in the power save mode 8-8
Code No.
Destination
Normal
machine
Zoom
machine
4 14 Japan
1 11 U.K.
5 15 AB series other than U.K.
6 16 U.S.A.
7 17 Inch series other than U.S.A.
25 35 Indonesia
Code
No.
Operation
mode
Operation
0
Normal
mode
When the fusing temperature reaches
the specified level, the main motor stops.
1
Long
mode
The main motor keeps rotating until the
completion of the warming up.
10 – 5