FTP Server/Client Scheduler
• “MultiplePanels”optionbutton
You can select and control panels from up to 25 panels.
• [ConnectionSetting]
A list of connected panels appears when you click
[Connection Setting].
Addpanelstothelistthefirsttimeyouusethisfunction
by clicking [Add].
Setting Description Default
RS-232C
COM port COM1~COM256 COM1
Baud Rate 9600,19200,38400 9600
LAN
Host name or IP
address
Enter the host name or the IP address of the panel to be
controlledwithin32alphanumericcharacters.
-
Data port
Enteradataportnumberbetween1025and65535forthe
panels to be controlled.
10008
Username
Entertheusername,ifoneexistsforthepanelstobe
controlled,in8charactersorless.
-
Password
Enterthepassword,ifoneexistsforthepanelstobe
controlled,in8charactersorless.
-
Panel’s ID
Select IDs in order to identify panels when PCs are connected
in a daisy chain.
(No daisy chain), 1-255
(No daisy
chain)
• “PowerONthepanelbeforestartingupthissoftware.”checkbox
Whenthischeckboxischecked,thepowerofthepanelisturnedonwhentheClientScheduleris
started.
• “PowerOFFthepanelbeforeexitingthissoftware.”checkbox
Whenthischeckboxischecked,thepowerofthepanelisturnedoffwhentheClientScheduleris
terminated.
• “SynchronizethepaneltimewithPCtimebeforestartingupthissoftware.”checkbox
Whenthischeckboxischecked,theclockofthepanelissettothetimeoftheviewerPCwhenthe