124
Status Monitoring Tool
Setting the operation environment
Setadvancedsettingsforpanelstatusacquisition.
1. From the [Option] menu click [Operation environment].
The[Settingofoperationenvironment]dialogboxwillappear.
2. Set the options.
1) Checkthe“ResponseconfirmationofviewerPC
throughICMPECHOpacket”checkbox.(Compulsory)
Thecheckboxcannotbecleared.
•Timeout(seconds)
Setsthetimeoutvalueforconfirmingaresponsefrom
theviewerPC.Valuesoffrom1-10secondscanbe
selected.
•Retrycount
Setsthenumberofretriespermittedwhenconfirming
aresponsefromtheviewerPC.Valuesoffrom1-10
times can be selected.
Ifthereisnoresponse,adelayof“timeoutvaluexnumberofretries”secondswilloccur.
2) “Acquisitionofdisplayingprograminformation”checkbox
CheckthisboxtoacquireinformationaboutthecurrentlydisplayedprogramfromtheviewerPC.
3) “AcquisitionofscreencapturedisplayingbyviewerPC”checkbox
CheckthisboxtoacquirethecurrentlydisplayedscreencapturefromtheviewerPC.Theacquired
screen captures will be displayed as thumbnails.
Itmaynotalwaysbepossibletoacquirescreencapturesofmovies.
4) “Statusacquisitionofpanel(PNseries)”checkbox
CheckthisboxtoacquireinformationaboutthepanelfromtheviewerPC.
ThisfunctioncanbeusedonlywiththeSHARPLCDmonitor(PNseries).
5) “Acquisitionoflicenseinformation”checkbox
CheckthecheckboxtoviewthelicensecodeandthefileversionoftheSHARPDigitalSignage
Software viewer version.
6) “Autoacquisitionunderthefollowinginterval”checkbox
Checkthisboxtoautomaticallyacquirepanelstatusatregularintervals.
•Acquisitioninterval
Settheintervalatwhichyouwanttoobtainpanelstatus.Valuesof1-60minutescanbeset.
3. Click [OK].
Setting the operation environment