Specifications

Maxiva UAX
October 17, 2013
531
8882693004 WARNING:Disconnectprimarypower priortoservicing.
Copyright©2013,HarrisBroadcast
STEP 4 IfdualLPUsareinusesettheTCUDriverControltoManual.SelecttheLPU
tobecalibratedastheactiveLPU.
STEP 5 TurntransmitteronbypressingtheOnbutton.UsetheTCUOnbuttonfor
dualsystems.UsetheLPUOnbuttonifasingleLPUisinuse.
STEP 6 SetbothlinearandnonlinearRTACtoBypass.ThisisdoneviatheLPUfront
panelLCDorviatheLPUGUIscreenshowninFigure514onpage523.
STEP 7 TurnSoundCarrieroff.ThisisdoneonAnalogSetupscreen3showninFigure
516onpage524.
STEP 8 RaiseUDCpowerto120mW(average)bypressingtheRaisebuttonwhile
monitoringthepowerlevelonthepowermeter.
STEP 9 Setsynclevelto100%withoutputpowerat120mW.Thisisdoneby
increasingordecreasingtheSyncLevelOffsetonAnalogSetupscreen1
showninFigure515onpa
ge524.Thepoweroutputwillneedtobereset
to100%af
terthesynclevelisadjusted.Thismaytakemultiplestepstoget
propersynclevelatfullpowerlevel.
STEP 10 Onfrontscreen,selectSETUP>XMTRPOWERSETTINGS>POWER
CALIBRATION.Onthewebbrowser,selectUAXHome>Config>CAL.
STEP 11 HighlighttheUDCcalibrationmenuitem.SelectUDC.
STEP 12 RaisepowerandcalibrateatthefirstdBmlevelandthentheseconddBm
levelperinstructionsonthescreen.Setpowerto5dBm(4mW)and
20.79dBm(120mWaverage,200mWpeak)andcalibrateperinstructionson
thescreen.
STEP 13 Uponcompletionofthecalibrationprocedure,thescreenwillpromptyouto
reconnectcables.Select“OKonLCDscreenorSaveonwebbrowsertoexit
theprocedure.Selectcanceltoterminatethecalibrationprocess.
STEP 14 Proce dur ecomplete.
5.6.5 CalibrateLPUOutput
LPUoutputreferstothelowpowerunittypeNconnectorlocatedontherearoftheLPU.TheLPUoutputis
relativelylinearwithfrequencysorecalibrationoftheLPUoutputistypicallynotrequiredinthefieldunlessthe
systemconfigurationisbeingchangedortheLPUisbeingre
placed.
Equipment and Tools Required:
Directionalcouplerandaveragepowermeterorotherprecisionpowermeasurement
means.
STEP 1
Connectacalibratedcoupler,suchasaNarda3020,totheLPUoutput(RF
OU TPUT“Nconnector)andconnectaloadofatleast100wattstothe
coupler.
STEP 2 OnthefrontscreenselectSETUP>SYSTEMSETTINGS>MODELNO.andthen
usetheupordownarrowstochangethemodelno.toUAX100.
STEP 3 PresstheLPUONbutton.
STEP 4 OnfrontscreenselectSETUP>XMTRPOWERSETTINGS>POWER
CALIBRATION.
STEP 5 UsetheUPcursorkeytoselectLPU.
STEP 6 Connectthepowermetertoaforwardportonthecoupler.
STEP 7 RaisepowerandcalibrateatthefirstdBmlevelandthentheseconddBm
levelperinstructionsonthescreen.
STEP 8 SetthepowertothelowerdBmlevelandthentheupperdBmleveland
calibrateperinstructionsonthescreen.
STEP 9 Oncompletionofthefinalcalibrationprocedurethemenuwillpromptyou
toselect“Continue”toexittheprocedure.