Specifications
Section-5 Maintenance
October 17, 2013
5‐14
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypower priortoservicing. 888‐2693‐004
Caution
PAB POWER METERS ARE CALIBRATED AT TIME OF FACTORY FINAL TEST.
DO NOT ALTER POWER METER CALIBRATIONS UNLESS POWER
READINGS ARE CLEARLY IN ERROR. CONSULT FACTORY TEST DATA
SHIPPED WITH TRANSMITTER, PAYING PARTICULAR ATTENTION TO LPU
OUTPUT AND PA MODULE CURRENTS, TO DETERMINE IF METERING MIS-
CALIBRATION IS A POSSIBILITY TO BE INVESTIGATED.
STEP 1 Connectaveragepowermetertoaprecisiondirectionalcouplertemporarily
installedatthePABoutput.Thecoupleroutputshouldbeattachedtoa1kW
load.Ifthedirectionalcouplerwassuppliedwithtransmitter,consultthe
stickersnexttosampleportsforcouplingvaluein‐dB.Ifnocouplingfigureis
ava
ilable,measurethecouplingvaluewithnetworkanalyzer.
Note
Do not forget to include loss of hook-up cables in measurement!
STEP 2 UsetheLCDcontrolbuttonsontheLPUtoselect SETUP>XMTRPOWER
SETTINGS>P OWERCALandthenPABLK#FORWARD.
STEP 3 RaisepowerandcalibrateatthefirstdBmlevel.SelectSaveandthenraise
powertotheseconddBmlevelperinstructionsonthescreen.
STEP 4 Uponcompletionofthefinalcalibrationprocedurethemenuwillprompt
youtoselect“Save”(orcontinue)toexittheprocedure.
STEP 5 ProceedtoPABreflectedcalibrationifrequired,orreconfiguresystemto
resumenormaloperation.
5.4.8 CalibratingPABReflectedPower
STEP 1 ConnectacalibratedcouplertothePABoutputandconnecta1kWloadto
thecoupleroutput.Thisproceduremustbeusedtocalibrateeachpower
amplifierblockinthesystem.
STEP 2 UsetheLCDcontrolbuttonsontheLPUtoselect SETUP>XMTRPOWER
SETTINGS>P OWERCALIBRATION.
STEP 3 UsethecursorkeystoselectPA1REFLECTEDorPA2REFLECTED,etc.
STEP 4 Withthecouplerinthesystem(asabove)measurethepowerattheforward
couplerport(don’tusemeteroffsetforthis).Theactualpoweroutofthe
couplerwillbeusedasareference.
STEP 5 Forthefirstpowerlevelrequestedinthereflectedcalibrationroutineyou
willturnupPABpoweroutputuntila‐16.5dBmpowerlevelatthecoupler
portisachievedfora500WPAB.Fora250WPABthelevelshouldbe‐
22.5dBm
STEP 6 Whenthe‐16.5or‐22.5dBmlevelisachieveddisconnectthepowermeter
andconnectashortSMAcablefromthecouplerporttotheREFIN
connectoronthebackofthePABbeingcalibrated.
STEP 7 PressSA VE.Thiswillmovethecalibrationroutinetothenextstepandask
youforanewdBmlevel.
STEP 8 Connectthepowermetertotheforwardcouplerportandthistimeincrease
theoutputpoweruntilyouread+3.5dBmonthemeterfora500WPABor‐
2.5dBmfora250WPAB.Whenthatlevelisattaineddisconnectthepower
meterandconnectashortSMAcablefromthec
ouplerporttotheREFIN
connectoronthebackofthePABbeingcalibrated.
STEP 9 SelectSave(orcontinue)toexitthereflectedcalibrationprocedure.
STEP 10 RestorethePABtoitsinitialstate.RepeattheprocedureforthenextPABto
becalibrated.