4.3.12 BatteryBackup,UPS(FutureOption)
ThisUPSversionofbatterybackupboard(9710051012G)willrequireuseofthelowvoltagePSboard9710051
011G.
Note
Current versions of the low voltage PS board (971-0035-007) use battery backup board assembly (971-
0035-003G ).
TheUPSbatterybackupboardinterfacesdirectlytotheLVPSboard.ThreeLithiumioncellsareusedinaseries
arrangementandprovide9.6voltsat1200mAh,12WHrrated.Thebatterybackupassemblyconsistsofabattery
backupcircuitboardwiththreeLithiumioncellspermanentlyattached;italsoincludesacu
stombatterycharging
circuitandprotectioncircuitry.Thebatteriesandcircuitboardaresoldasaunitwhenreplacementbatteriesare
required.
Thebat
terybackupassemblypartnumberis9710051012G.
Theb
atterybackupsuppliestheLVPSboardwith+6.4Vto10.8Vat20Amaximum.ItismounteddirectlytotheLVPS
board.AblockdiagramofthebatterybackupassemblyisshowninFigure49.
Thebat
terybackupassemblyspecificationsareasfollows.
Rechargetimeforthefullydischargedbatterypackistwotothreehours.Thechargecyclestartsandstops
basedonthebatterypackoutputvoltage.
Undertheoptimumbatterycondition,thisbatterybackupoptioniscapableofoneminuteofoperationof
themodulatorportionoftheUAXtransmitterfollowinganacpowerfailure.Thisisaccomplishedbykeeping
the+24V,+12V,+12Vosc,+5V,and‐12Vpowersupplyinterfaceboarddcoutputsenergizedforoneminute
f
ollowingapowerfailure.Duringthistimethe PAassemblyisnotpowered.
ItkeepstheoscillatorcircuitsandtheinternalGPSreceiveroperatingforanadditionalfifteenminutesfollow
ingth
eoneminutemodulatorbackupoperation.Itaccomplishesthisbydeenergizingallbutthe+12Vosc
powersupplyoutputs.
Duringthelastfifteenminutesofbatter ybackupoperation,thebatterybackupmaintainspowertothe
10MHzand1PPSInputcircuitryontheSignalProcessingboardandtheFPGA,OCXOandGPScircuitryonthe
PFRU.Bypoweringthesecircuitsthemodulatorcanmaintainthe10MHzOCXOdisciplineloopwhenthe
t
ransmitterlosespower.TheOCXOcantakethreeminutestostabilizefromacoldstartandthediscipline
loopitselfcantak eanhourtoreachthemaximumprecision;havingthedisciplineloopactiveduringapower
outageenablestheUAXtransmittertoreturntoairfasterwithgreaterfrequencyaccuracy.
Figure 4-9 Battery Backup Block Diagram