Specifications

Maxiva UAX
October 17, 2013
395
8882693004 WARNING:Disconnectprimarypower priortoservicing.
Copyright©2013,HarrisBroadcast
3.8.13 StatusScreens‐Analog
Figure 3-90 LPU Analog Status Screen 1
Table387XmtrHome>ExciterHome>Status>AnalogModulator)
Field Explanation
Input Thisin
dicatesthe(videoandaudio)InputSwitchModesetting.
InputDev
(InputDevia
tion)Thisindicatestheamountofvariationofthevideoinputfromthestandard1
voltpeaktopeaklevel.OdBrepresents1voltpeaktopeak.Thisvalueisdeterminedbythe
formula .
White
(mV)Thisisthein
dicationoftheblankingtowhitevoltageleveloftheinputvideo.700mVis
typical
SyncLev
el
(SyncLe
velinmV)Thisistheindicationoftheblankingtosyncvoltageleveloftheinputvideo.
300mVistypical.
ResidualCa
rrier
(%)Thisistheindic
ationofvideocarrierdepthofmodulationatwhite,comparedtothepeak
ofsynclevel.12.5%istypical.ThisindicationisaresultoftheResidualCarriersettingfrom
Table359onpage366.
VFSignal
(VideoFo
rmatSignal)OK=validvideoinput,Error=invalidormissingvideoinput.This
indicatorisOKifthemainvideoinputsignalispresentandiswithinspecifications.
WhiteLim
iterActive
Thisindic
atordisplaysOffiftheWhiteLimiterisOff,anddisplaysOniftheWhiteLimiterisOn.
RefertoTable359onpa
ge366.
dB 20
peak to peak video voltage
1 volt peak to peak
----------------------------------------------------------------


log=