Note
The indicators on this screen display the status of the input commands described in Table 3-70 on page 3-
78. These inputs enter the transmitter via the 25 pin male Transmitter Interface connector on the LPU rear
panel. The connector pin numbers are provided.
Note
The UAX Transmitter will default to standalone mode when no connections are made to the parallel I/O.
If the TCU present signal is asserted at anytime, the transmitter will be forced into dual mode for opera-
tions with a TCU. The transmitter will remain in dual mode until power cycled with the TCU present sig-
nal de-asserted. When in dual mode, the parallel I/O will be operational regardless of remote control
setti
ng enabled/disabled. When in standalone mode, the parallel I/O will be disabled when remote control
is disabled
.
RemoteEnable
IndicatedtheremotecontrolstatusoftheLPU.Greenisenabled,Blueisdisabled‐inputonpin5.
Note:InStandaloneoperation,theRemoteControlcommandisignored.
AutoPowerCtrl
Auto/ManualPowercontrolcommand.GreenisAuto,BlueisManual‐inputonpin18.Note:In
Standaloneoperation,theAutoPo
werCtrlcommandisignored.
Excit erOFF T r ansmitterOffCommand.Greenisactive,Blueisinactive‐inputonpin4
TCUPresent TCUPre s en tIndication.Greenisactive,Blueisinactive‐inputonpin19.
ExciterON TransmitterOnCommand.Greenisactive,Blueisinactive‐inputonpin3
RestrikeCmd
ManualFaultResetCommand.Whe
nintheOnstate,thiscommandwillresettheautomaticfault
restrikeprocessing.Greenisactive,
Blueisinactive‐inputonpin17
Table370Status>TransmitterI/O
Field Explanation