Copyright©2013,HarrisBroadcast
3.7.7 RemoteCommsSetupScreens
Figure 3-37 LPU Ethernet Screen 1
Note
Dual LPU systems use the rear Ethernet ports for communications with the TCU. LPU A and LPU B must
have their Ethernet ports set as follows:
Table3‐26UAXLPUHome>ExciterHome>Setup>R emoteCommunications
Field Explanation
RearEt
hernet
MACA
ddress RearEthernetportMAC(MediaAccessControl)addressisdisplayed.
Mode
SelectDH
CP(DynamicHostControlProtocol)orStatic.IfStaticisselected,clickintoandfill
fields(obtainedfromyourITsystemadministrator):IP,Gateway,&SubnetMask.
Apply S
electApplysoftkeytoimplementchanges
FrontEt
hernet:ForinformationonhowtoconnecttotheFrontEthernetport,seeSection"2.13.1LPUAccessvia
Ethernet"onpage2‐21.
MACA
ddress FixedMACaddressisdisplayed.Thisisrequiredtochangefeaturekey.
IPAdd
ress FixedIPaddressisdisplayed.
Table3‐27DualLPUEthernetSettings
Setting LPUA LPUB
Mode Static Static
IPAdd
ress 192.168.2.2 192.168.2.3
Gateway 192.168.2.100 192.168.2.100
SubnetMa
sk 255.255.254.0 255.255.254.0