Instruction manual
repair! . If you do not have one of these labels, and would like some please
contact NMT.
Magnets should not be allowed near the R-Series Detectors (no closer than a foot or
so), and never in the central tunnel.
The Diverter Gate should be thoroughly rinsed, paying special attention to the
hollow doors and the underside of the doors and beaks, which can accumulate a
considerable amount of fish slime. The bumpers on the gate doors may ”glue”
shut with fish slime or after periods of no use. Carefully “peel” the bumpers away
from the gate beak before you use the gate.
The gate is very sturdy, but it should be handled carefully to avoid bending. In
particular, the door latches require precise alignment and this can be ruined if the
unit is bent.
The R-Series detector and gate are shipped with a 12-volt DC sealed lead acid
battery and a battery charger. Recharge your 12-volt battery as needed
(instructions are with the battery charger). Disconnect the battery from the
detector or gate when not in use or when charging.
Part 6: Troubleshooting
Sensitivity Adjustment
Several situations affect the ability of the R-Series Detector to function properly.
Stray magnetic fields around the detector, movement of the entire detector in the
form of wobble or vibration, and flexing of the central tube slightly by forcing fish
into it or having live fish slap it hard all create magnetic fields which can cause
false positives. Magnetic sand and dirt particles will also affect reliability.
Stray magnetic fields are initially difficult to judge, but once seen by the
operator of the detector, will be obvious. If the detector sensitivity is normally set
at about 11:00 o'clock, to attain the 2
nd
and sometimes 3
rd
LED setting, but it is
suddenly necessary to turn down the sensitivity to achieve the same display
when at a new location or the same location with new equipment around, there is
probably equipment in the vicinity causing strong magnetic fields. This will
generate a moving magnetic field, similar to that of a tag. Depending on the
severity, it may be necessary to move either the detection equipment or the
offending electrical equipment or reroute electrical cables. Someone working
R-Series Instruction Manual 36