Receptacle Box Cover
3-Pronged plug
(6-20P) R-25JTF
3-Pronged, Receptacle
(6-20R)
230 V
230 V
208 V
208 V
(A)
GROUNDING INSTRUCTIONS
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord
having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly
installed and grounded.
WARNING – Improper use of the grounding plug can result in a risk of electric shock. The electrical
requirements are 120 Volt, 60 Hz AC only, 20 Amp or more (R-22GTF); and 20 Amp or more (R-25JTF) 
fused electrical supply. It is recommended  that  a  separate  circuit  serving  only  this  appliance  be 
provided.  When  installing  this appliance, observe all applicable codes and ordinances. If it is necessary 
to use an extension cord, use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot 
receptacle that will accept the plug on the appliance. The marked rating of the extension cord should be 
AC 120 Volt 20 Amp (R-22GTF), AC230/208 Volt 20 Amp (R-25JTF). Consult a qualified electrician or 
serviceman if the grounding instructions are not completely understood or if doubt exists as to whether 
the appliance is properly grounded.  
230/208V 20A
R-25JTF
120V 20A
R-22GTF
Receptacle Box Cover
3-Pronged plug
(5-20P)
3-Pronged, Receptacle
(5-20R)
Radio or TV Interference
Should there be any interference  caused  by  the microwave oven to your radio or  TV,  check that the 
microwave  oven  is  on  a  different  electrical circuit, relocate the radio or TV as far away from the 
oven as feasible or check position and signal of receiving antenna.
VOLTAGE SELECT
The R-25JTF has been preset for 208V operation. 
If you need to change this oven for 230V operation,
follow instructions below.
1. Unplug oven.
2. Remove one screw(A) from the Voltage Select
Cover  located  on  back  of  the  oven  near  the
bottom.
3. Remove the Voltage Select Cover and rotate 180
degrees.
4. Reinstall  the  Voltage  Select  Cover  using  one
screw(A) removed in Step 2.
5. Plug power cord into wall outlet.
Your oven is now ready for 230V, 60Hz operation.
Note: If “EE4” or “EE5” appears in the lighted digital
display, a voltage adjustment must be made.