Specifications
Appendix
ProtoMat 95s/II 65
› Clean both parts of the working depth limiter using the brush
supplied.
When clean, the working depth limiter is reassembled in reverse order
and the spindle is reinserted into the retaining block.
› Always check that the insertion depth of the spindle is correct before
starting up. The stop ring must sit on top.
The distance between the drill tip and machine base plate must be
0.5 mm when the head is lowered.
The machine may not be able to drill through the board if the
distance is too great.
› Finally retighten the screws (
3
) and put the plug back into the
spindle.
fig. 47:
› Check the distance when reassembling the plotter spindle.
The machine may be damaged if the distance is too small when
drilling.
Caution! Use only graphite to lubricate the working depth limiter.
9.2 SerialPort 1 serial connection
The SeralPort1 serial data channel is an RS 232-C standard port with
electrical isolation and is used for communication between the control
unit and the PC.
The SerialPort1 data transmission rate is programmed using DIL
switches 1 and 2.
Switch 1 Switch 2 Baud rate
OFF OFF 4800 baud
ON OFF 9600 baud
Default setting
OFF ON -
ON ON -
0.5mm