Specifications
Computer-controlled functions
16 ProtoMat 95s/II
4.2 Reprogramming the machine data
You will have to re-enter the PAUSE or HOME position data in the
machine settings if the PC operating system crashes and the head no
longer moves to these positions.
Proceed as follows:
fig. 2:
fig. 3:
› Click
UNLOCK
.
This activates the SET HOME and INITIALIZE push button.
› Click on
INITIALIZE
.
The device moves to all four end positions. The device then comes to
a halt in the zero position (at the front right). The traverse range thus
determined is displayed under SIZE and saved by BoardMaster.
See the BoardMaster Manual for more detailed information.
The coordinates for the HOME position are generated automatically.
The X value is set at
0
and the Y value corresponds to half the
valuespecified for Y under
SIZE
.