Technical information

LSM Operator Panel
2-4 Tenth Edition 9871
8
RESET
Switch Sends an interrupt message to the LCU
software.
This switch initiates an error dump of the
memory contents in the LCU.
Note: When the memory dump is complete,
you must IPL the LSM.
9
IPL
Switch/
Indicator
Switch: Resets LSM hardware and initiates an
IPL process.
Indicator: Lights when an IPL process is being
performed.
10
PROC ACTIVE
2
Indicator Lights if processor is functioning.
11
MASTER LMU
2
Indicator Lights when this LMU is the master LMU in a
dual LMU configuration. Blinks briefly when
this is the standby LMU in a dual LMU
configuration and polls the master LMU.
12
SERVICETEK
2
Indicator Lights when a problem has been detected in
the ACS and an alert message and error code
have been sent to the Remote Center or
operator console.
13
SERVICE REQ
2
Indicator Lights when the processor has detected an
error in the LMU. The LMU does not operate
under this condition.
Note: If this indicator is lit, contact Customer
Support Services.
Notes:
1. Numbers match the item numbers in Figure 2-1 on page 2-2.
2. This appears on the LSM operator panel of an LSM that is attached to a 9315 EM.
Table 2-1. LSM Operator Panel (Continued)
Item
1