Table 8.3 shows the rated contacts for switch SW1 (See Figure 8.2).
Table 8.3 Rated Contacts for Switch SW1
Resistance Load
(cos φ=1)
Rated Current
250 V AC 3 A
125 V AC 6 A
30 V DC 4 A
Recommended Minimum
Voltage and Current
2 V, 0.1 A AC/DC
Minimum Cut-Off
Voltage and Current
1 V, 10 mA AC/DC
Table 8.4 shows rated contacts for relays CR5 to 11 (See Figure 8.2).
Table 8.4 Rated Contacts for Relays CR5 to 11
Resistance Load
(cos φ=1)
Induction Load
(cos φ=0.4)
(L/R=7 ms)
Rated Load
110 V AC 0.3 A
24 V DC 1 A
110 V AC 0.2 A
24 V DC 0.3 A
Rated Current 2A
Maximum Contact
Point Voltage
125 V AC
125 V DC
Maximum Contact
Point Current
2 A
Maximum Open/Close
Capacity
AC: 60 VA
DC: 30 W
AC: 22 VA
DC: 10 W
Minimum
Applicable Load
100 mV DC 10 μA