Instruction manual

STP-200/300/400 Series Instruction Manual
5.6 Remote Operation
(Read through Section 8, "Remote Input/Output Signal Connector"
before use.)
Slide the "MANUAL/REMOTE" changeover switch on the rear panel to
"REMOTE."
5.6.1 Powering ON
1) Switch "ON" the breaker on the rear panel.
(A metal fitting is attached to the breaker to lock the breaker at the "OFF"
position. Loosen the screw, lower the metal fitting, switch "ON" the breaker,
then tighten the screw.)
2) Input 24 V DC between (1)-(13) (POWER ON) of the REMOTE CONNECTOR
(CON40) for 0.3 seconds or more ((1): "+" side; (13): "-" side).
The magnetic bearing functions, and the rotor levitates.
The "POWER ON/OFF" switch built-in lamp lights (POWER ON state).
Although the POWER ON operation may cause an "Abnormality/Error
Warning" lamp to light and an alarm signal to be output from the
REMOTE CONNECTOR, this is not an indication of abnormality.
This state is released within 5 seconds.
5-6