3) Connecting the Power (Primary Side) Cable
Connect the primary power cable to the "AC POWER CON30" on the STP control
unit rear panel as shown in Table 4.1.
Table 4.1 Connecting the Power Cable
CON30
Pin No.
Cable Color Remarks
1 (L) Brown
2 (N) Blue
Single phase 200 V AC ±10% (for 200 V specification)
Single phase 220 V AC ±10% (for 220 V specification)
Single phase 240 V AC ±10% (for 240 V specification)
Single phase 100 V AC ±10% (for 100 V specification)
Single phase 110 V AC ±10% (for 110 V specification)
Single phase 120 V AC ±10% (for 120 V specification)
Both 50/60 Hz
3 (PE) Yellow/Green Ground
Rear Panel
"AC POWER"
Outline of
connector
NPEL
Secure the power cable to the STP control unit rear panel using the cable fitting
tool (See Figure 4.7).
Confirm the power voltage on the name plate.
Connect the power cable securely to prevent incorrect wiring.
DO NOT apply surge voltage exceeding 1 kV to the input power line.
Always ground power cable to prevent electric shock.