Instruction manual
STP-200/300/400 Series Instruction Manual
16.2 Specifications for the STP Control Unit
Table 16.2 Specifications for the STP Control Unit (1/2)
Item Specifications
Input voltage V AC
200±10%, 220±10%, 240±10%, 100±10%,
110±10%, 120±10%
(Depends on voltage spec.)
At start: VA 500
Input power
Under rated operation: VA 150
Input frequency Hz 50/60±2
Input phase Single phase
Motor drive system 3-phase transistor-inverter
Output voltage or less rated operation
(3-phase) V AC
45
Output frequency or less rated operation Hz 800
Ambient temperature range °C 0 to 40
Storage temperature range °C - 25 to + 55 (excluding a battery)
Battery storage temperature range °C - 20 to + 40
Weight kg 27
Dimensions mm W482.6 × H132.6 × D473
Battery used 12 V 7 Ah x 2 (Japan Storage Battery Co.,
Ltd./Small-Sized Sealed Lead-Acid
Battery/PORTALAC series PE12V7F1)
Operation switches [Front Panel]
•
POWER ON/OFF
(Illuminated alternate push button switch,
black/green)
•
MOTOR START
(Momentary push button switch, black)
•
MOTOR STOP
(Momentary push button switch, red)
[Rear Panel]
•
MANUAL/REMOTE Changeover
(Toggle switch)
Panel indication lamps [Front Panel]
•
ACCELERATION (Green LED)
•
NORMAL OPERATION (Green LED)
•
EMERGENCY OPERATION (Red LED)
•
FAILURE (Red LED)
•
OVER TEMPERATURE (Red LED)
•
BATTERY OPERATION (Red LED)
[Switch Built-In Lamp]
•
POWER ON (POWER ON/OFF, green)
16-2