Service manual

R-671 - 31
TEST DATA AT A GLANCE
PARTS SYMBOL VALUE / DATA
Special fuse F1 15A / 250V
Fuse F2 F 8A
Thermal cut-out (HVT) TC1 145°C Off / 115˚C On
Thermal cut-out (OVEN) TC2 150°C Off / 130˚C On
Grill heating element (top) GH1 Approx. 76 / Insulation resistance > 10 M
Bottom heating element GH2 Approx. 132 / Insulation resistance > 10 M
Oven lamp OL 230–240 V 25W
High voltage capacitor C AC 2100V 1.02µF
Magnetron MG Filament < 1 / Filament – chassis ohm.
Power transformer T Filament winding < 1
Secondary winding Approx. 143 / Primary winding Approx. 2.6
WARNING: DISCONNECT THE PLUG WHEN MEASURING RESISTANCE.