Product manual
Maintenance and Repair
6-12
Part 1105120-01
E 2013 Nordson Corporation
Internal Blower Lamphead Complete Cover Removal (contd)
Lifting Bottom Cover
Unicable Receptacle Clearing Cover
Figure 6-14 Removing the Cover
7. Pull the cover the rest of the way up and off the lamphead and set it
aside.
Internal Blower Lamphead Cover Replacement
1. Slide the bottom cover down over the lamphead until the unicable
receptacle drops into the slot and the 8 holes at the bottom of the cover
line up.
2. See Figure 6-13. Replace the 8 screws at the base of the lamphead (4
front and 4 rear). Install the two screws into the cover on both sides of
the unicable receptacle. Tighten the screws to 1.35 NSm (12 in-lbs).
3. Reconnect the blower cable and install the screw next to the plug.
4. See Figure 6-12. Replace the top blower cover and secure with 6
screws (3 front and 3 rear). Tighten the screws to 1.35 NSm (12 in-lbs).
5. Refer to page NO TAG. Reconnect the unicable to the lamphead.