Product manual
Maintenance and Repair
6-11
Part 1105120-01
E 2013 Nordson Corporation
Internal Blower Lamphead Complete Cover Removal
1. Disconnect the unicable from the lamphead.
2. See Figure 6-12. Remove the top blower cover by removing the 6 M4 x
10 Philips screws (3 front and 3 rear) and set aside.
3. Remove the 2 M4 x 20 screws on either side of the unicable receptacle.
Removing Screws from Top Cover
Removing Screws at Unicable Receptacle
Figure 6-12 Removing Top Blower Cover
4. See Figure 6-13. Remove the M4 x 10 Philips screw next to the blower
cable receptacle. Unplug the blower cable from the receptacle.
5. Remove the 8 screws at the base of the lamphead (4 front and 4 rear).
Remove Blower Plug
Remove 8 Screws
− 4 Front and 4 Rear
Remove Top Screw
Figure 6-13 Removing Blower Plug and Screws
6. See Figure 6-14. Lift the bottom cover straight up and then push the
unicable receptacle into the cover until it clears the cover housing.