Product manual
Operation
4-10
Part 1105120-01
E 2013 Nordson Corporation
Multiple Units Networked to a Master Unit
Operated Locally
Single Unit
Operated Locally
Step
5 Set the POWER SETTING.
1. Press the SET-SAVE button on the
POWER SETTING selector until the
power level is displayed.
2. Press the UP or DOWN arrows to set the
desired power level. The power level
changes immediately.
3. Press the SET-SAVE button to save the
setting and exit the power setting
function.
NOTE: The power level can be changed at
any time during operation with the lamp ON
or OFF.
Set the POWER SETTING.
1. On the master unit, press the SET-SAVE
button on the POWER SETTING selector
until the power level is displayed.
2. Press the UP or DOWN arrows to set the
desired power level.
3. Press the SET-SAVE button to save the
setting.
4. Set the POWER SETTING at each
remote unit between 20 and 100 using
the same procedure as the master unit.
Each remote POWER SETTING can be
different.
The actual power output of each remote
is dependent on the Master POWER
SETTING.
For example, if your master unit POWER
SETTING is 80 and your first remote unit
POWER SETTING is 50, the actual
output of the first remote unit will be 0.5 x
0.8 or 40%.
NOTE: In most cases, remote units should
be set to 100%.
6 External Blower Units: Turn on the external blower. If there is insufficient pressure the
system faults and FAULT LOW LAMPHEAD PRESSURE is displayed. (Check for proper
pressure with the appropriate instrumentation.) The internal blower automatically turns on
and off as required.
Continued...