Product manual
Operation
4-9
Part 1105120-01
E 2013 Nordson Corporation
Correcting a Fault Condition
Correcting a fault condition
Total Seconds
Max 60 seconds
25 seconds
Display reads fault condition (message scrolls).
Correct the reason for the fault, then push SYSTEM OFF button.
Display reads C DELY.
Press SYSTEM ON button.
Display reads WARMUP.
Display reads LMPDLY.
Display reads LAMPON.
Startup
Locally Operated Units
Table 4-4 Startup Procedures for Locally Operated Units
Step Single Unit
Operated Locally
Multiple Units Networked to a Master Unit
Operated Locally
1 Switch system electrical power ON.
2 Turn the main power switch on the front of the system controller unit to the ON position.
After a brief power-up test sequence, OFF appears on the display.
3 Make sure that all interlocked access doors are closed and that external cooling and
exhaust fans are running if not directly connected to the system controller blower contacts. If
external interlocks are wired and open, FAULT EXT INTERLOCK will be displayed.
4 On the NETWORK selector, press LOCAL. Set the NETWORK configuration.
S On the master unit NETWORK selector,
press LOCAL.
S On the remote unit NETWORK
Selectors, press REMOTE.
Continued...