Product manual

Operation
4-8
Part 1105120-01
E 2013 Nordson Corporation
Timing Sequence with Idle = N
(Also see Table 3-5)
Powering ON the System Controller
Total Seconds
12 seconds
Turn on main disconnect switch on front panel.
Controller goes through initial boot sequence with a full display test.
When complete, controller displays OFF.
Changing system status from OFF to LAMP ON
Total Seconds
25 seconds
Press SYSTEM ON button.
Display reads WARMUP.
Display reads LMPDLY.
Display reads LAMPON.
Changing system status from LAMP ON to STANDBY
Total Seconds
20 seconds
Display reads LAMPON.
Press STANDBY button Once.
Display reads L COOL.
Display reads STDBY.
Changing system status from STANDBY to LAMP ON
Total Seconds
10 seconds
Display reads STDBY.
Press SYSTEM ON button.
Display reads LMPDLY.
Display reads LAMPON.
Changing system status from LAMP ON to OFF
Total Seconds
60 seconds
Display reads LAMPON.
Press SYSTEM OFF button.
Display reads C DELY.
Display reads OFF.
Shutdown timing at completion of process allows for proper cooling.