RF Detector Installation
See Figures 3-3 and 3-6 for RF Detector connections and Figure 3-16 for
dimensions.
S The RF detector shuts down the system controller when the RF level
detected is above the calibrated trip level. This can happen if the
lamphead RF screen is torn or incorrectly installed.
S One RF detector is normally required for every 16 networked units within
one curing enclosure. However, some applications and systems may
require a RF detector on each unit. Contact your Nordson representative
for more information.
S Do not mount the RF detector directly below the lamphead.
S The RF detector can be damaged by excessive heat and extreme RF
fields. Do not install it less than 8 inches from the lamphead.
S Mount the RF detector so that the antenna faces the lampheads and is
between the operator and the lampheads or the lampheads and any
opening (the major source for RF leakage).
S The detector has a patented self test feature to make sure it is working
properly. The detector is not serviceable. If it fails, fault code 26 appears
on the system controller. Replace the RF detector if it fails.