Product manual

Installation
3-15
Part 1105120-01
E 2013 Nordson Corporation
Optional Mounting Kit for Lampheads
An optional adjustable bracket, mounting plate, and screws are available as
a kit for flexible mounting of lampheads. Refer to page 7-13 in Parts for the
kit part number and mounting instructions.
Adjustable
Mounting
Bracket
Figure 3-11 Optional Adjustable Mounting Bracket
Light Shielding
Personnel in the area should be shielded from the UV light.
S Provide adequate shielding of UV light. The lamphead must be enclosed
so that no UV light is allowed to escape.
S Any louvered material used for exhaust must be a light-shielding design.
S If UV light does escape the operator must wear approved UV-protective
clothing and eyewear.
Cooling Air Installation
Internal Blower Lampheads
Internal blower lampheads do not require a cooling air source. However, the
flow of cooling air must not be restricted or impeded, either at the inlet or the
outlet. If an AirShield ventilation system or any type of exhaust-restricting
devices are used, the exhaust air must be evacuated to ensure adequate
cooling air flow. Refer to the AirShield Ventilation System instructions on
page 3-17.