Hardware Specifications
The hardware design of the DeviceNet Interface follows ODVA
recommendations. The interface can be found on the rear of the CoolWave2
system controller.
Interface Connector
Sealed micro connector is specified in ODVA specifications Volume 1,
Release 2.0, Errata 2. Appendix C, table C.3. CoolWave2 uses a Phoenix
connector.
Indicators Red and green LEDs indicate the status of the module and the network.
Node Address Switches Two 10-position rotary switches for setting the MAC ID.
Data Rate Switch A 10-position rotary switch to set the data rate to 125, 250, or 500k Baud.
Software Specifications
Refer to Section 10 for the DeviceNet Interface Module specifications.
Lamphead Installation
The lamphead mounting must include provisions for UV light shielding and
cooling air ductwork and venting. Each application has different constraints
and therefore requires custom-designed enclosures and light shielding.
Contact Nordson UV systems engineering department for help with designs.
Mounting Guidelines
Figures 3-9 and 3-10 provide the physical dimensions of the CoolWave 2
lampheads. See page 2-5 for focal lengths. Install lampheads with focus
reflectors with the base positioned as follows:
2.1 focus reflectors: 53.3-mm (2.1-in.) above the substrate
3.1 focus reflectors: 78.8-mm (3.1-in.) above the substrate
NOTE: Flood reflectors have no set distance. The base to substrate
distance is not as critical and can be adjusted to vary the dosage and
intensity.
Lamphead
2.1 or 3.1 inches
53.3 or 78.8 mm
Substrate
Lamphead Base
Figure 3-8 Focus Reflector Lamphead Mounting