Product manual

Description
2-3
Part 1105120-01
E 2013 Nordson Corporation
DescriptionComponentItem
6 Magnetrons The magnetrons are 3 KW, 2450 MHz generators that convert high
voltage electrical inputs to RF energy.
6A Waveguide The wave guide directs the RF energy into the UV bulb, exciting a
UV-emitting plasma within the bulb.
7A External Blowers
Forced air is used to cool the UV bulb and magnetrons. If external
blowers are used, they must be sized appropriately to provide the
required air flow. Contact Nordson UV engineering for external cooling
air guidance.
7B Internal Blower
8 Temperature
Sensor
Monitors the lamphead internal temperature. The sensor consists of a
thermistor potted to a ring-tongue terminal and cable, which is
connected to the light detector board.
9 System Controller Provides and controls high voltage to the lamphead magnetrons and
controls other system functions.
10 RF Detector Detects leakage of microwave radiation. Will shut down system if
radiation is detected.
1
7A
6
5
2
3
1
4
10
8
9
7B
1
Internal Blower LampheadExternal Blower Lampheads (Mounted on Curing Machine)
6A
Figure 2-1 System Components (Typical UV Curing System Setup)