Product manual
DeviceNet Specifications
10-15
Part 1105120-01
E 2013 Nordson Corporation
Lamp Object (64
HEX
−
16 Instances)
Class Attributes (Instance 0)
Attribute
ID
Name
DeviceNet
Data Type
Data
Value
Access
Rule
1 Revision UINT 1 Get
100 System Ready:
0 – Not Ready
1 – Ready
255 – DeviceNet Disabled (not reported over
DeviceNetJ)
USINT 0 Get
101 Faulted Node Bitmap:
Bit 0 – Master
Bit 1 – Slave 1.....Bit 15 – Slave 15
UINT 0 Get
102 Units Present Bitmap:
Bit 0 – Master
Bit 1 – Slave 1.....Bit 15 – Slave 15
UINT 1 Get
103 Master Lamp State
1 – Off
2 – Filament On Time Delay
3 – Standby
4 – Lamp Start
5 – Lamp On
6 – Fault
7 – Reset
8 – Cool Off
9 – Lamp Cool
10 – Test
11 – Start Power Delay
USINT 0 Get
104 Master Lamp Fault
See S−Device Supervisor for bit definitions
UDINT 0 Get
105 Master Light Intensity Level Set (0−100%) USINT 0 Get
106 Master Magnetron Power Level Actual (0−100%) USINT 0 Get
110 Master Lamp Command:
1 – Off
2 – On
3 – Standby
5 – Reset
USINT 0 Get / Set
111 Light Intensity Command
20−100% (0−255% accepted)
USINT 0 Get / Set