Product manual
DeviceNet Specifications
10-7
Part 1105120-01
E 2013 Nordson Corporation
Assembly Object (04
HEX
– 2 Instances)
Class Attributes (Instance 0)
Attribute
ID
Name DeviceNet
Data Type
Data
Value
Access
Rule
1 Revision UINT 2 Get
2 Max Instance UINT 112 Get
100 Polled Input Assembly Instance
(valid values are 100)
UINT 100 Get / Set
101 Polled Input Size UINT 14 Get
102 Polled Output Assembly Instance
(valid values are 112)
UINT 112 Get / Set
103 Polled Output Size UINT 4 Get
Instance Attributes (Instances 100 and 112)
Attribute
ID
Name
DeviceNet
Data Type
Data
Value
Access
Rule
3 Data USINT 0 Get / Set