Technical data

4. Service procedures
1
12
3
4
5
IV - 8
Wired remote
controller
display
Wireless remote
controller
display
Possible causes of troubles
Thermistor failure
Operation lamp
and heat stand-by
lamp flash
alternately.
O: Operation
lamp
O: Timer lamp
:Heat stand-
by lamp
Indoor thermistor is either
open or short.
Outdoor thermistor is either
open or short.
Indoor coil temp. (E1 = TH2) cannot be detected.
Indoor coil temp. (E2 = TH3) cannot be detected.
Indoor room temperature cannot be detected.
Discharge gas temp.A (PC compressor=TH0A) cannot be detected.
Outdoor coil liquid temp. (C1 = TH0E) cannot be detected.
Outdoor coil gas temp. (C2 = TH0C) cannot be detected.
:Operation
lamp
O: Timer lamp
:Heat stand-
by lamp
Protective device for
compressor is activated.
PC compressor motor is overloaded.
PC compressor motor is locked.
Compressor current detection circuit is defective.
Low-pressure protector is activated.
(Low pressure switch or low pressure prevention.)
Standard comp. contactor (Mg SW)is chattering.
F01
F02
F10
F04
F06
F07
H01
H02
H03
H06
H18
Fault with
compressor
and its circuit
O: flashes
: OFF