Technical data
1. Specifications
1
12
3
4
5
I - 116
1-11 Installation Instructions
Electrical Characteristics
Indoor Unit : ADR 425 H Outdoor Unit : AER 425 SCL3E
AER 425 SHL3E
● Cooling
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220 - 240 V / 1 phase / 50 Hz 380 - 415 V / 3 phase / 50 Hz
Rating conditions
A 0.84 / 0.9 0.62 / 0.65 4.45 / 4.35 4.89 / 4.8
kW 180 / 210 0.13 / 0.15 2.5 / 2.52 2.81 / 2.88
Full load conditions
A 0.84 / 0.9 0.62 / 0.65 5.3 / 5.32 5.74 / 5.76
kW 180 / 210 0.13 / 0.15 2.98 / 3.02 3.29 / 3.38
Starting amperes A 1 / 1 1 / 1 25 / 28 27 / 30
● Heating (Heat pump only)
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220 - 240 V / 1 phase / 50 Hz 380 - 415 V / 3 phase / 50 Hz
Rating conditions
A 0.84 / 0.9 0.62 / 0.65 5 / 4.8 5.44 / 5.25
kW 180 / 210 0.13 / 0.15 2.79 / 2.81 3.1 / 3.17
Full load conditions
A 0.84 / 0.9 0.62 / 0.65 5.1 / 4.9 5.54 / 5.35
kW 180 / 210 0.13 / 0.15 2.87 / 2.89 3.18 / 3.25
Starting amperes A 1 / 1 1 / 1 25 / 28 27 / 30
Cooling:
Rating Conditions : Indoor Air Temperature 27°C DB / 19°C WB
Outdoor Air Temperature 35°C DB
Full Load Conditions : Indoor Air Temperature 35°C DB / 23°C WB
Outdoor Air Temperature 43°C DB
Heating:
Rating Conditions : Indoor Air Temperature 20°C DB
Outdoor Air Temperature 7°C DB / 6°C WB
Full Load Conditions : Indoor Air Temperature 24°C DB
Outdoor Air Temperature 21°C DB / 15.5°C WB