SECTION 3: WIRING AND INSTALLATION T200 User's Manual
PAGE 3-57
3.14.2 Motor Power Cable
Wire the motor power connector in accordance with Figure 3.32, Figure 3.33, Figure 3.34 and Figure 3.35.
Use wire sizes based on the motor’s continuous stall current (r m s) and wire length requirements.
For proper drive commutation of G400 series motors, it is required that the motor phase conductors, Phase U (A), Phase
V (B), and Phase W(C) be wired exactly as shown in Table 3.7.
3.14.3 T200 Resolver Cable
Wire the motor resolver connector in accordance with Figure 3.35.
NOTE
:- Avoid running the resolver cable near other high power wiring, especially the motor
power cable, if possible.
Wiring must be in accordance with standard EN 60204-1 (See Section
2 of this Users Manual.)
Required for
CE-Compliance