User`s manual
T200 User's Manual SECTION 3: WIRING AND INSTALLATION
PAGE 3-44
3.12.2 120Va.c. Control-Backup Power Daisychaining
Connections to wire the 120Va.c. control backup power are shown in Figure 3.21.
1 2 3
L N PE
IN
Connector TB6
1 2 3
L N PE
OUT
Connector TB6
T200-XX0
24AWG (0.25mm
2
) Wire. Wiring needs to take 0.3Arms/axis, add axis requirements.
1 2 3
L N PE
IN
Connector TB6
1 2 3
L N PE
OUT
Connector TB6
T200-XX0
120Va.c.
Backup
Daisy-
Chained
to other
T200's
ISOLATED
120Va.c. Logic
Backup Power Source
L N PE
Figure 3.21: Daisy-Chaining the 120Va.c. backup Input from one T200 to the Next T200