User`s manual

SECTION 3: WIRING AND INSTALLATION T200 User's Manual
PAGE 3-43
3.12 Daisychaining Control-Backup Power Connections to T200's
The T200 contains extra connector terminals which allow easy connection of the 24Vd.c. and 120Va.c. control-backup
power.
3.12.1 24Vd.c. Control-Backup Power Daisychaining
Connections to wire the 24Vd.c. control backup power are shown Figure 3.20 below.
1 2
24V+ 24V-
IN
Connector TB5
Connector TB5
T200-XX0
Up to 18AWG (0.9mm
2
). Wiring needs to take 1.5A/axis, add axis
requirements
Twist 24V+ and 24V-Wires
1 2
24V+ 24V-
OUT
1 2
24V+ 24V-
IN
Connector TB5
Connector TB5
T200-XX0
1 2
24V+ 24V-
OUT
24V+/-
Daisy-
Chained to
further
T200's
User-Supplied
24Vd.c.
Inputs
Figure 3.20: Daisychaining the 24Vd.c. backup power from one T200 to the next
NOTE
:- The T200 contains a resetable fuse on the 24Vd.c. input. If the 24V backup power
is connected in reverse, then an over-current on the 24V+ and 24V- terminals will cause the
fuse to go open circuit. If the faulty connection is removed, the fuse will reset after a short
period.