SECTION 3: WIRING AND INSTALLATION T200 User's Manual
PAGE 3-31
3.8 Single Phase 230Va.c. Mains Configuration
The T200-310/410/510 Models only may be driven by single-phase 230Va.c.-mains input. In this case the following
user supplied options are required:-
1. Single-Phase Mains Circuit Breaker
2. Mains Contactor
For a control-backup power source, any of the following may be used:-
1. 24Vd.c. Power Source or
2. 120Va.c. Power Source. This power source must provide galvanic isolation between the 120Va.c. output (to be
connected to the T200) and the T200's a.c. mains inputs.
Note again, that if the a.c. mains is still applied, and the control-backup power is removed, then the T200 control section
will still operate correctly. Control power can still be generated from the high voltage D.C. Bus.
Figure 3.7 below outlines typical interconnect in a multi-axis T200 system, which is powered by single-phase 230V a.c.
mains.
NOTE - If the T200 is used in single-phase mode, an EMC a.c. mains
line filter is required to achieve conducted-emissions compliance.
Required for
CE-Compliance
CAUTION:- If the 120Va.c. logic backup power supply option is used, the
120Va.c. output for connection to the T200, MUST be galvanically isolated
from the T200's a.c. mains input, otherwise damage to the T200 may occur.