User`s manual
T200 User's Manual SECTION 1: T200 OVERVIEW
PAGE 1-10
1.5.2 Units with D.C. Bus Input Interface (T200-300, T200-400, T200-500)
All current ratings are specified in ampere r.m.s. unless otherwise stated.
Nominal D.C. Bus Voltage
325Vd.c. (generated from rectified 230Va.c.)
D.C. Bus Maximum Voltage
400Vd.c. (generated from rectified 280Va.c.)
Maximum Continuous Input Current
T200-300
5Ad.c.
T200-400
10Ad.c.
T200-500
20Ad.c.
Table 1.4: T200-X00 Power Ratings
1.5.3 Optional Control Logic Backup Power
D.C. Bus Minimum Voltage
(below which 24Vd.c. or 120Va.c. Control-Logic
Backup supply is needed)
250Vd.c. (generated from rectified 170Va.c.)
24V Input
18Vd.c. to 36Vd.c.
2.0A inrush current /axis
1.5A steady state
Internal Resettable fuse in case where polarity has been
reversed
120Va.c. Input
+10%, -15% voltage range
0.3Ar.m.s. /axis
Table 1.5: T200 Control Logic Backup Power Ratings