Service manual

6
R-426HQ
CONTROL PANEL ASSEMBLY REMOVAL
POSITIVE LOCK
®
CONNECTOR (NO-CASE TYPE) REMOVAL
Figure C-2. Positive lock
®
connector
1. Disconnect the power supply cord, and then remove outer
case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Push the lever of positive lock
®
connector.
5. Pull down on the positive lock
®
connector.
CAUTION: WHEN CONNECTING THE POSITIVE LOCK
®
CONNECTORS TO THE TERMINALS, CON-
NECT THE POSITIVE LOCK
®
SO THAT THE
LEVER FACES YOU.
1. Disconnect the power supply cord and then remove outer
case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the wire leads from panel components.
5. Remove the one (1) screw holding the control panel
assembly to the oven cavity front plate.
6. Slide the control panel assembly upward and remove it.
7. Now, individual components can be removed.
NOTE: 1. Before attaching a new key unit, wipe off remaining
adhesive on the control panel frame surfaces
completely with a soft cloth soaked in alcohol.
2. When attaching the key unit to the control panel
frame, adjust the upper edge and right edge of the
key unit to the correct position of control panel
frame.
3. Place the key unit firmly to the control panel frame
by rubbing with soft cloth not to scratch.
1.
Disconnect the power supply cord and remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Pull the wire leads from the oven lamp socket.
5. Remove the screw from the oven lamp socket.
6. Remove the oven lamp socket from the magnetron duct.
7. Remove the oven lamp from the socket by turning the
oven lamp.
8. Now, the oven lamp and the oven lamp socket are free.
OVEN LAMP AND LAMP SOCKET REMOVAL
Terminal
Push
Pull down
1
2
Lever
Positive lock¨
connector
Figure C-1. Oven lamp socket
Oven lamp
socket
Terminal