Technical data

I
INSPECTIONS
The Model 3196 parts must be inspected to the
following criteria before they are reassembled to
insure the pump will run properly. Any part not
meeting the required criteria should be replaced.
3. Inspect leading and trailing edges of the vanes for
\
pitting, and erosion or corrosion damage.
(Area ‘c” in Fig. 62.).
I
C
NOTE: Clean parts in solvent to remove oil,
grease or dirt. Protect machined surfaces
against damage during cleaning.
Casing
The casing (100) should be inspected for excessive
wear or pitting. It should be repaired or replaced if it
exceeds the following criteria (Fig. 61).
1. Localized wear or grooving greater than l/8 in.
(3.2 mm) deep.
2. Pitting greater than l/8 in. (3.2 mm) deep.
3. Inspect case gasket seat surface for irregularities.
100
Fig. 61
Impeller
1.
Inspect impeller (101) vanes for damage. Replace if
grooved deeper that l/l 6 in. (1.6 mm) or if worn
evenly more than l/32 in. (0.8 mm).
(Area “a’ in Fig. 62)
2. Inspect pumpout vanes for damage. Replace if worn
more than l/32 in. (0.8 mm).
(Area “b” in Fig. 62)
b
a
Fig. 62
Frame Adapter
1. Check frame adapter (108) for cracks or excessive
corrosion damage. Replace if any of these
conditions exist (Fig. 63).
2. Make sure gasket surface is clean.
t
46