Technical data

/
.,*
i:,:
lg. REMOVAL OF SEAL CHAMBER COVER
(Mechanical Seal)
1. Remove gland stud nuts (355).
2. Remove seal chamber stud nuts (370H).
3. Remove seal chamber (184).
4. Remove shaft sleeve (128), if used.
NOTE Mechanical seai is attached to sleeve
(726”. Rotary potion of seal needs to be .
removed from sleeve by loosening set screws
and sliding it off the sleeve. Refer to
mechanical seal instructions.
5. Remove gland (107) with stationary seat and
O-ring (360Q) (Fig. 28).
NOTE: Be careful not to damage the stationary
portion of the mechanical seal. It is seated in
the g/and bore.
126
Fig. 28
19+ REMOVAL OF STUFFING BOX COVER
(Packed Box) (Fig, 29)
1. Remove gland stud nuts (355), and gland(107).
2.
Remove stuffing box cover stud nuts (370H).
3.
Remove stuffing box cover (184).
Fig. 29
4. Remove shaft sleeve (126) (Fig. 30).
126
/
3
lg. 30
5.
Remove packing (106) and lantern ring (105)
from stuffing box cover (184) (Fig. 31).
38