Technical data

FEELER GAUGE METHOD
1.
Remove coupling guard. Refer to coupling guard
instructions in Appendix II.
2. Loosen jam nuts (4236) on jack bolts (371A) and
back bolts out about two turns (Fig. 20).
3.
4.
Tighten locking bolts (370C) evenly, drawing
bearing housing (134A) towards frame (228) until
impeller contacts the casing. Turn shaft to
ensure contact is made.
With a feeler gauge set the gap between the three
locking bolts (370C) and bearing housing (134A)
per impeller clearances in Table 3.
5. Evenly back out bearing housing (134A) using the
three jack bolts (371 A) until it contacts the locking
bolts (370C). Evenly tighten jam nuts (4238).
6. Check shaft for free turning.
7. Replace coupling guard. -