Specifications
‐7‐
C.2CHECKIMPELLERCLEARANCE
Beforestartingthepumptheimpellerclearancemustbechecked.Thepumpefficiencyismaintained
whentheproperimpellerclearanceisset.Impellerfrontclearanceisfactorysettopredetermined
limits.
Minimumvaluesfordifferenttemperaturesappearinthefollowi ngtable.Theimpellerclearance
adjustmentsarenecessarytopreventtheimpellerfromcontacting thecasingduetodifferential
expansionathigheroperatingtemperatures..
IMPELLERCLEARANCESFORSERVICETEMPERATURE
S
SERVICE
TEMPERATURE°F(°C)
MAGNATE 3575SX
inches(mm.)
MAGNATE 3575M&3575LX
inches(mm.)
MAGNATE 3575M&XLX
inches(mm.)
To200°F(93°C) 0.005”(0.13mm) 0.008”(0.20mm) 0.010”(0.26mm)
250°F(93°C‐121°C) 0.007”(0.18mm) 0.010”(0.26mm) 0.010”(0.26mm)
300°F(121°C‐149°C) 0.009”(0.23mm) 0.010”(0.26mm) 0.019”(0.48mm)
350°F(149°C‐177°C) 0.011”(0.28mm) 0.010”(0.26mm) 0.021”(0.53mm)
MODEL911S
.)
MODEL911My911LX
SECTIOND
PUMPSTART‐UP
D.1STARTINGPUMP
1. Ensurethatsuctionvalveandanyrecirculationorcoolinglineshavebeenopened.
2. Completelycloseorpartiallyopendischargevalveasdeterminedbysystemconditions.Never
opendischargevalvemorethan25%onstartup.
3. Startdriver.Observepressuregauges.Stopdriverifdischarge pressureisnotattainedquickly.
Re‐primeandattempttorestart.
4. Opendischargevalveslowlyuntilthedesiredflowisobtained.Ifnormallevelsofvibration,
bearingtemperatureandnoiseareexceeded,shutthepumpdownandresolvetheproblems.
5. Topreventdamageresultingfromcavitationorrecirculationalwaysoperatethepumpator
neartheratedconditions.
6. Ifthespecificgravityisgre aterthanoriginallyassumedortheratedflowrateisexceededthe
drivercouldoverload.Thefollowingtableshowsminimumrecommendedflows.
7. Alwayschangecapacitybyregulatingthevalveinthedischargeline.Neverthrottleflow
fromthesuctionside,whichcancausecavitationandseriousdamagetothepump.