Operating instructions
8
Change the rotating direction of the electric
motor by inverting the poles on the plug.
RCA 380 E :
Connect the RCA 380 E to the thee-phase electric
power source:
•
Nominal voltage: 400 V / 50 Hz
•
Minimum Power Cable Size: 4 mm²
•
Plug: 32A-CCE 3P+N+E 400V
•
Nominal Current of the Main Fuses: 32 A
•
Connection Power: 21,2 kW
Warning!
Before completing the connection of the machine
it is necessary to check the rotating direction of
the cutting chain and/or electric motor. Wrong
rotating direction can cause damages to the oil
pump.
3.1 DISCHARGE CONVEYOR ASSEMBLY (in case of separate delivery)
Hydraulically driven discharge conveyor is also a component part of the firewood processor.
•
Place the discharge conveyor on the ground and move it closer to connecting spot
•
Slide the discharge conveyor on the supporting forks and secure it with two screws (1– Figure:3)
•
Fasten the lifting package by fixing rope pulleys to their position (2-Figure: 4).
•
Use the hand winch (3-Figure: 3) to lift the discharge conveyor slightly above the desired height and
attach the carrying chain (4-Figure: 3).
•
Loosen the wire rope, so that the weight of discharge conveyor is distributed between the wire rope and
carrying chain (4-Figure:3)
•
Connect the hydraulic connectors (a & b)
II
I
3
1
3
4
a
b
a
b