Operating instructions

18
Hydraulic oil – suitable brands: (Viscosity: 46 mm
2
/s at 40
o
C)
Manufacturers: Substitute oils:
Castrol Hyspin AVH 46
Mobil DTE 16
Renolin B 46 - HVI Shell TELLUS T46
BIPI Energol SFA 46
SETRAL Poclain
5.5 OIL FILTER MAINTENANCE
Check and/or clean the oil filter when the first oil change is performed. Presence of small aluminum partic-
les, caused by running-in of the pump is expected.
Clean the filter insert using gasoline. Work in open areas and take necessary precautions to prevent fire.
Using an air compressor, blow the filter insert from inside out.
Filter insert must be replaced only if the filter gets mechanically damaged.
Bad filter permeability is shown on the filter gauge if the gauge indicator is in the red zone when oil is
heated to operating temperature. Change the oil filter
5.6 LUBRICATION OF THE ANGLE MULTIPLICATION GEAR (RCA 380)
Oil quantity and grade: 1.2 l (0,32 gallon), SAE 75 (Renolin CLP 100 DIN 51 517/13)
Replace the oil when changing the reduction gear bearings.
5.7 CUTTING CHAIN LUBRICATION
Never operate the machine without lubricating the chain first!
Chain lubrication oil quantity: 8 L
Approximate oil consumption: (0.6-1.0) L/h
Quality chain lubrication oils with viscosity grade of 95 mm
2
/s at 40ºC are recommended.
Never use used oils!
The flow of the cutting chain lubrication oil can be regulated depending on
the oil quality, using a regulation screw (Figure: 18). It is factory set to
maximum!
18