Instruction manual
1-50 20. 2 Port Adapter (ZM-1MD2)
4) When a power supply is switched on where a console is connected to the
ZM-1MD2, a console will become a communication time-out before completing
initialization of the ZM-1MD2.
When it connects again or reset operation of a console is performed once it,
removes the cable of a console, it will return to a normal state. (Normal operation of
this machine is carried out after 15 seconds progress from the time of a power
supply injection.)
4. When you use ZM-1MD2 for A series/FX series CPU, set time-out time as 1.5 seconds
or more by communication parameter setup of ZM41/70/80.
Attachedmetal fittings of ZM-1MD2
When connecting ZM-1MD2 to the small type (A1S, A2US, etc,) of A series PC made by
Mitsubishi, use the unit by mounting the attached metal fittings.
GPP
ON
ON
GPP
Unused
Tighten correctly
Insert the metal fitting
as shown in the drawing.
After inserting,
tighten it correctly
49
16
7
Size of metal fitting
MELSEC Axsxxx
MITSUBISHI
POWER
MELSEC AxS
CPU
RUN L.CLR
ERROR RESET
RUN
STOP
RESET
MITSUBISHI
MELSEC Axsxxx
MITSUBISHI
POWER
MELSEC AxS
CPU
RUN L.CLR
ERROR RESET
RUN
STOP
RESET
MITSUBISHI
(Used for A series large type,
or used when connecting to
Q series)