Instruction manual
1
16. Terminal Converter (ZM-1TC) 1-39
Hardware Specifications
16. Terminal Converter
(ZM-1TC)
Use the terminal converter ZM-1TC when connecting the ZM-300/ZM-42 to 82 series and
PC by the RS-422/485 terminal block.
Installation
Tighten mounting screws with the following torque.
Tighten terminal screw, module mounting screw
Size
CN2
C
N
1
MJ2 MJ1
DC24V
T
B
1
S
W
1
CN1
Unit Mounting
Screw
Unit Mounting Screw
ZM-1TC (Terminal Converter)
Never fasten these screws too tightly, otherwise the cover of Control Terminal may be deformed.
Position of screws
I/O, I/F terminal screw
Screw
size
M3
Tighten torque
(N m)
Pressure connection terminal
(Unit : mm)
0.49
5.9MAX
5.9MAX
Module mounting screw
M2.6
0.1 0.2
34.7
25
65
1. Make sure that the power of ZM-300
/ZM-42 to 82 series is OFF.
2. Install the ZM-1TC to the serial
connector (CN1) of the ZM-300/ZM-
42 to 82 series.
3. Settle the ZM-1TC by the module
mounting screw.