Instruction manual

4
1. Ethernet 4-11
Network Communications
The contents of the system setting vary depending on the method selected. Check the
connecting method and make the setting on the ZM-71SE editor.
(A) Connecting to the PLC through RS-232C or RS-485 interface
1. PLC type setting
Select [System Setting] [PLC Type] and select the PLC to be used.
2. Communication parameter setting
Select [System Setting] [Comm.
Parameter]. Attach a check mark ( ) to
[Use Ethernet].
3. Select [System Setting] [Network Table
Setting] [Ethernet] . The network
table edit window is displayed. Edit the
network table. For more information on
network table editing, refer to page 4-14.
(B) Connecting to the PLC on the Ethernet
1. PLC type setting
Select [System Setting] [PLC Type] and select the PLC that shows [xxxxx
(Ethernet)]. The following PLC models are supported.
*1 For AUI connection, a transceiver is required.
- The memory use is the same as the one for 1 : 1 connection. (Refer to “Chapter 5
Connection to PLCs.”
* The data code of the ZM-300 series is fixed to the binary code. Be sure to set the binary
code for the data code on the PLC.
PLC Model
Section on ZM-71SE
PLC Unit Connection
QnA series
(Ethernet)
Q2A, Q3A, Q4A
Q2ASx
AJ71QE71, AJ71QE71-B5
A1SJ71QE71-B2,
A1SJ71QE71-B5
10BASE-T connection:
Twist-pair cable
Category 5
AUI connection
*1
:
AUI cable
QnH (Q) series
(Ethernet)
QnH (Q mode) QJ71E71, QJ71E71-B2
FA-M3/FA-M3 R
(Ethernet)
FA-M3
FA-M3 R
F3LE01-5T, F3LE11-0T