Instruction manual
4-8 1. Ethernet
Transferring Screen Data
This section describes the procedure for transferring screen data from the ZM-71SE editor
on the server to ZM via Ethernet. For the procedure using the ZM-80C cable, refer to the
Manual.
Prerequisites
When screen data is to be transferred for the first time via Ethernet or when the ZM-300
series has been replaced due to trouble, the server cannot transfer screen data because
the network table has not been transferred to the ZM-300 series. In this case, the following
setting must be made on the Main Menu screen:
- IP address
- Default gateway
- Subnet mask
Note that this is the tentative setting. The port number must be “10000.” When the network
table is transferred from the ZM-71SE editor, the above data is updated.
• Setting procedure
1. Press the [Ethernet] switch on the Main Menu screen.
2. The Ethernet screen is displayed. (For more information, refer to “Chapter 2 LCD
Control Terminal Operations.”) Set the IP address. If necessary, set the default
gateway and subnet mask. (When attaching the I/F unit to ZM-300, set the
connecting method (10BASE-T/AUI) as well.)
3. When the setting has been completed, press the [Setting Finished] switch. The
Main Menu screen is displayed again.
4. The setting data can be reviewed on the Main Menu screen.
5. Transfer screen data from the server.
Time-Out : 0.50 sec
2002-4 -1 07:23:30
SYSTEM PROG. VER. 1.010
FONT
VER.1.300 / 1.000 / 1.000
ENGLISH
I/F DRV VER.1.310
YOKOGAWA FA-M3
Ethernet
Editor:MJ1
Main Menu ZM-371TA
System Information
PLC Type : YOKOGAWAFA-M3/FA-M3R(Ethernet)
Comment :
Screen Data
Information
Size : 5783552
SRAM/Clock
Ethernet
Card
Menu
I/O Test
Retry : 3
PORT: 10000
MAC: 0050FF000035
Ethernet Information
PORT: 10000
MAC: 0050FF000035
Trans.Speed : 10BASE-T
Stat. No. : 192.168.1.68
Ethernet Information
Trans.Speed : 10BASE-T
Error : Stop
Stat. No. : 192.168.1.68