Instruction manual

4
1. Ethernet 4-3
Network Communications
Notes on Ethernet Communications
For ZM-300 (high-performance):
To use Ethernet communications on ZM-300 (high-performance), use the 10BASE-T
connector (LAN) provided on the unit. It is not possible to use Ethernet or FL-net
(OPCN-2) communications by attaching the network module ZM-80NU/80NU2 to
ZM-300 (high-performance) at the same time. When ZM-80NU/80NU2 is mounted, the
10BASE-T connector (LAN) provided on the unit cannot be used.
When using Ethernet communications with ZM-80NU/80NU2 mounted, the Web server
or e-mail function cannot be used.
For ZM-300 (standard):
To use Ethernet communications on ZM-300 (standard), the ZM-80NU/80NU2 must be
mounted. When ZM-300 (standard) is equipped with the ZM-80NU/80NU2, it becomes
Ethernet-ready. In this case, however, the Web server or e-mail function is not
available.
IP Address for the ZM-300 Series
To enable Ethernet communications on the ZM-300 series, it is necessary to set the IP
address for identification of the ZM-300 series on the network. The IP address should be
set on the Main Menu screen of the ZM-300 series. For more information, refer to “Chapter
2 LCD Control Terminal Operations.”
Communication Network Module ZM-80NU/80NU2
Specifications of ZM-80NU/80NU2
Specifications
Item AUI
10BASE-T
10BASE5 10BASE2
Baud rate 10 Mbps
Transmission method Base band
Maximum network
distance or maximum
node interval
2500 m (5 segments) 925 m (5 segments) 500 m (4 HUBs)
Maximum segment
length
500 m 185 m
100 m
Between the node and the
HUB
Maximum number of
nodes
100/segment 30/segment 2/segment
Minimum node interval 2.5 m 0.5 m None
Connecting cable
Ethernet coaxial cable
(50 )
RG58A/U, RG58C/U
coaxial cable (50 )
UTP
(unshielded twisted pair)
22-26AWG